× All the transactions performed on 2.0 is available here. To access Market click "Home".

Megger MPQ1000 Three Phase Power Quality Analyzer Hand Held with 3 Nos current Clamps (MEGGER)(MPQ1000)

` 590,000.00

  • MRP: `656000.00

Megger MPQ1000 Three Phase Power Quality Analyzer Hand Held with 3Nos current Clamps is an advanced 8 channel 3-phase Analyzer. It has key features like automatic CT recognition CTs are powered by the unit so there is no need for additional connections. Connection verification ensures the unit is configured correctly and you get the data you need. On-board data analysis saves time by allowing an immediate examination of data before leaving the site. Multiple communication methods USB, Ethernet, USB stick or32GB SD card allow for flexible and convenient operation.1000Vdc measurement allows testing and analysis of renewable applications dismissing the need for additional equipment. CATIV@600V assures a safe unit for all applications. IEC 61000-4-30 Class A compliant current ranges 60 A, 600A, 3000A and 6000A. For more info please refer datasheet of OEM. Warranty Three years on main instrument, one year on accessories. Price including GST@18percent.Delivery period 45days..

  • Availability: 3 In Stock
  • Min. Qty. Per Consignee: 1
  • Display type - VGA Backlit
  • Display Mode - Scope Mode and DVM Mode
  • Number of Current Channels - 4 Nos.
  • Facility to Measure RMS Voltage - Available
  • Measurable voltage resolution - 16 Bit / .055V instantaneous reading Volts Volts
Other Specifications Download Specification
Type Of Power Analyzer Three phase
Display Type VGA Backlit
Display Mode Scope Mode and DVM Mode
Number Of Current Channels 4 Nos.
Number Of Voltage Channels 4 Nos.
Facility To Measure RMS Voltage Available
Measurable Voltage Range 0 to 1000V Volts Volts
Measurable Voltage Accuracy 0.1 Udin for 10 to 150 Udin
Measurable Voltage Resolution 16 Bit / .055V instantaneous reading Volts Volts
Facility To Measure RMS Current Available
Measurable Current Range 0 to 6000A Ampere
Measurable Current Accuracy 1 of reading per IEC61000-4-30 +CT
Measurable Current Resolution 0.000165 x Ifs instantaneous reading Ampere
Facility To Measure Active, Reactive And Apparent Power Available
Maximum Power That Can Be Measured 18MW total for 3 phases KW KW
Power Accuracy 1.75 U * I + CT affects max maximum error due to 1 phase error
Power Resolution 16 bit Watt Watt
Facility To Measure Active, Reactive And Apparent Energy Available
Facility To Measure Sag(dips) And Swell(surge) Available
Facility To Measure Frequency Available
Frequency Range That Can Be Measured 42.5 to 69.0 Hz Max harmonic freq.: 69 x 50 = 3450 Hz Hz
Facility To Measure Total Harmonic Distortion Available
Accuracy In Measurement Of Total Harmonics Distortion 0.05 x THD or 0.35
Resolution In Measurement Of Total Harmonics Distortion 16 bit
Facility To Measure Inter Harmonics Available
Order(n) To Which Facility To Measure Harmonics Available 50 on MPQ 80 on PC
Facility To Measure Power Factor Available
Accuracy In Measurement Of Power Factor 0.0175 for PF
Facility To Measure Distortion Factor Available
Accuracy In Measurement Of Distortion Factor NA
Facility To Measure Ripple Factor Available
Accuracy In Measurement Of Ripple Factor NA
Facility To Measure Voltage And Current Unbalance Available
Facility To Measure Inrush Current Available
Facility To Measure Flicker Available
Facility To Measure Crest Factor Available
Measurable Crest Factor Range NA
Measurable Crest Factor Accuracy NA
Measurable Crest Factor Resolution NA
Screen Memory Yes
Data Transfer Software Provided For Analysis On PC Yes
Internal Memory 32GB SD Card MB MB MB
Type Of Battery Used NiMH Battery pack
Battery Backup upto 8 Hours Hours Hours Hours
Power Supply(volts In AC) 230
Weight Of The Analyser 1.82 Kg Grams Grams
Dimensions(LXWXH) 175x250x60mm cmXcmXcm
Provision For External SD Card Yes
Operating Temperature Range -20 to +50 degree celsius degree celsius degree celsius
Operating Humidity 0-95 %
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer As per Data Sheet
Compliance To IEC 61000-4-30 Yes
Category Of Safety Rating CAT-IV 600V
Dry Heat Test As Per IS :9000(Part 3/Section 5) Yes
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) Yes
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) Yes
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. Yes
Type Test Report No. R-2550P-2
TTC Report Date 16 SEPTEMBER 2016
Name Of Lab RT Laboratories
Address Of Lab Harleysvile USA
Interface USB/Ethernet