cyber power ut2200e - in 2200va1320w (cyber power)(cyber power ut2200e - in 2200va1320w)

` 7,751.00

  • MRP: `8613.00

GeneralUPS TopologyLine-interactiveInputGenerator CompatibilityYesNominal Input Voltage Vac230 10Input Voltage Range Vac165 290Input Frequency Hz50 1060 10Input Frequency DetectionAuto-sensingRated Input Current A10Input Connector TypeSchuko OutputCapacity VA2200Capacity Watts1320On Battery WaveformSimulated Sine WaveOn Battery Voltages Vac230 10On Battery Frequency Hz50 160 1Automatic Voltage Regulation AVRSingle Boost, Single BuckOverload ProtectionCircuit BreakerOutlets - Total4Outlet TypeSchuko x 4 Outlets - Battery Surge Protected4Typical Transfer Time ms4BatteryRuntime at 60W min95Runtime at 90W min70Typical Recharge Time Hours8Start On BatteryYesUser-replaceableNoBattery TypeSealed Lead-acidSurge Protection FilteringSurge Suppression Joules125EMI/RFI FiltrationYesPhone/Network Protection RJ11/RJ45 Combo1-in, 1-outManagement CommunicationsLED Indicators.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM
  • Input - Single phase sinewave(160-280v) Volt
  • Rated Output - Single phase sinewave 230v AC , 50Hz Volt
  • variation in AVR output in AC mode - 9 %
  • Inverter Efficiency - 77 %
Other Specifications Download Specification
Rating In KVA/ Min VAH Capacity Of Battery 2.0/800 KVA/VAH
Technology MOSFET-PWM
Input Single phase sinewave(160-280v) Volt
Rated Output Single phase sinewave 230v AC , 50Hz Volt
Load Power Factor 0.6
Variation In AVR Output In AC Mode 9 %
Variation In Output Voltage In Battery Mode 10 %
Variation On Output Frequency In Battery Mode 0.5 Hz
Inverter Efficiency 77 %
Total Harmonic Distorsion 40 %
Switching Over Time 10 Mili sec
Overload 10 %
Overload Time 10 Minutes
Protection Against Short Circuit Of UPS Yes
Protection For Outside Input Voltage Range 280 Volt
Protection Against Discharge Per 12v Battery 10.5 Volt
Degree Of Protection IP-21
Type Of Battery Tubular confirming to IS:13369
Type Of Enclosure Mild steel
Dry Heat Test At 45 Degree For 16 Hrs As Per IS:9000 Pt-3/sec-5 Yes
Damp Heat Test At 45 Degree , RH -95% For 2-cycle As Per IS:9000 Pt-5/sec-1 Yes
Cold Test As Per IS:9000 Pt-2/sec-4 Yes
Availability Of The Type Test Report From Central Govt./NABL/ILAC Accredited Lab Yes
Type Test Certificate No. And Date Registration/CRS2015-0794/R-41016861 Date:18.08.2017
Name Of Lab BIS
Address Of Lab Manak Bhaban,9, Bahadur Shaha Zafar Marg, New Delhi-110002