Mercury Free Sphygmomanometer (crown)(DXJ-210)

` 3,300.00

  • MRP: `4200.00

The mercury free sphygmomanometer design to be used as LCD instead of mercury column, Semi-automatic, Dual-use type, creating an easy to use product for hospitals Clinics and homes..

  • Availability: 5,000 In Stock
  • Min. Qty. Per Consignee: 20
  • Conformity to Indian Standrad for SPHYGMOMANOMETERS - NA for digital
  • ISI MARKED - NA for digital
  • CM/L No and validity date - N/A
  • Type - Portable
  • Range: Pressure measurement - 0 to 300 mmHg
Other Specifications Download Specification
Type Of SPHYGMOMANOMETERS(B.P.Apparatus) Digital
Conformity To Indian Standrad For SPHYGMOMANOMETERS NA for digital
ISI MARKED NA for digital
CM/L No And Validity Date N/A
Measuring Device Mechnical
Type Portable
Measurement Method Auscultatory method
Display For Digital BP Instrument: LCD(Liquid Crystal Digital) Display
Range: Pressure Measurement 0 to 300 mmHg
Range:Pulse Measurement For Digital With Accuracy ± 5%. 40 to 200 per minute
Accuracy:Pressure Measurement ± 3 mmHg
Pressure Detection Capacitive Pressure sensor
Inflation Manual
Deflation And Rapid Air Release Manual
Cuff Range Small (18-22)cm
Dimensions Of The Equipment 360 X 96 X 66 mmXmm
Dimensions Of The Display Screen 340 X 25 mmXmm
Operating Temperature 0 to 55 °c
Stroage Temperature (-10) to 55 °c
Power Source:Chargeable 4 Nos AA Size Batteries.Operated With Battery Charger(for DIGITAL). Yes
Type Of Battery(4 Nos AA Size) Alkaline
Automatic Power Off If System Is Idle For 3 Minutes. Yes
Weight 1.1 Kgs
CE Marking Certificate For B.P. Apparatus Model. Yes
For Digital Sphygmomanometer ,Availability Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A). Dry Heat Test (For 16 Hrs At A Temp. Of 55degree C In Accordance With IS: 9000/part-3/section-3/1977)latest. Yes
B). Cold Test(For 4 Hrs At A Temp. Of (-10) Degree C In Accordance With IS: 9000/part-2/section-3/1977latest. Yes
C).Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 55 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981)latest. Note:- The B.P.Instrument Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, B.P.Instrument Shall Be Functional. " Yes
Availability Of Type Test Report Covering Complete Test Parameters As Per IS3390 Latest For Mercurial And IS7652 Latest For Aneriod Type, From Any ILAC/NABL Accredited/Central Gov. LAB.For Digital Type Including Environmental Test From Any ILAC/NABL Accredited/Central Gov. LAB Yes
Test Cetificate No. AS PER OEM
Test Report Date AS PER OEM
Name And Address Of The Lab Where Test Conducted. AS PER OEM
Others Certificate Ie ROHS,WHO,GMP Etc. AS PER OEM
Conformity To OILM-R-16-1 And OILM-R-16-2 For Both Non-invasive Mechanical Sphygmomanometers And Non-invasive Automated Sphygmomanometers Are For Guidance And All The Gazette Of India Related To Legal Metrology Issued Time To Time, Are Applicable To The Specification As Well As To The Product. Yes
Warranty Time 1 Year