× All the transactions performed on 2.0 is available here. To access Market click "Home".

fluke-t6-1000, electrical tester with field sense technology (fluke)(fluke-t6-1000)

` 20,085.00

  • Offered Price: ` 20600.00
  • MRP: `25750.00

Electrical Tester with FieldSense technology,Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage. Without opening covers or removing wire nuts. On wires up to AWG 4/0 120 mm2, carrying as much as 200 A. It will change your job. Safer. Faster. Easier.Simultaneous voltage and current display shows all power supply measurements at a glance for efficient trouble shooting,1 to 1000 V ac or dc,0.1 to 200 A ac ,Resistance 1 ohm to 100 k Ohm, Frequency measurement 45 Hz to 66 Hz,HOLD button temporarily freezes the reading for easy viewing,Easy to read display with backlight,Standard two-year warranty..

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - Backlit
  • Measurement Type - True RMS
  • AC Current Measurement Range - 0 to 999.9 Ampere
  • AC Voltage Measurement Range - 0 to 1000 Volt
  • Inrush Current (Integration Time) - 100 millisecon
Other Specifications Download Specification
Type Hand Held
Display Backlit
Measurement Type True RMS
AC Current Measurement Range 0 to 999.9 Ampere
AC Current Measurement Accuracy + or - 2 %
AC Voltage Measurement Range 0 to 1000 Volt
AC Voltage Measurement Accuracy Upto 600 Volts + or - 1 %
AC Voltage Measurement Accuracy Beyond 600 Volts + or - 1.5 %
Inrush Current (Integration Time) 100 millisecon
DC Current Measurement Range 0 to 999.9 Ampere
DC Current Measurement Accuracy + or - 2 %
DC Voltage Measurement Range 1000 Volt
DC Voltage Measurement Accuracy + or - 1 %
Resistance Measurement Range 0 to 4000 Ohm
Resistance Measurement Accuracy + or - 1.5 %
Continuity < or = 30 Ohm
Frequency Measurement Range 10 to 400
Frequency Measurement Accuracy + or - 0.5
Jaw Size (Dia In Closed State) 17.8mm
Satety Rating Category III 600 V of IEC 61010 -2-D31
Operating Temperature Range -10 to 50 degree C Degree C
Operating Humidity (RH) 0 to 90 , 5 C to 30 C (41 F to 86 F) 0 to 75 , 30C to 40 C (86 F to 104 F) 0 to 45 , 40C to 50 C (104 F to 122 F) %
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
Standard Accessories Supplied With The Equipment Attached test leads with removable 4 mm probe caps, user documentation
Dimensions (H X W X L) 61.1X259.3X43.8 mm mm x mm x
Weight 350 Gms. gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. NABL/2561547
Test Report Date 01.01.2018
Name Of The Lab ACCUMEN NABL CALIBRATION LAB
Warranty 2 Year

Price Dekho Price Dekho Price List in india