× All the transactions performed on 2.0 is available here. To access Market click "Home".

Digital Earth Resistance Clamp Meter (HTC)(CE 8201)

` 49,900.00

  • MRP: `56000.00

HTC Digital Earth Leakage Clamp Meter provide high accuracy for low resistant measurement. This device includes data logging and alarm threshold setting.1999 Display, Large 3 4000 Counts LCD Display, Auto power Off, Conductor Size 32 x65 Max/Min, Data Hold, Low battery indication, Overload protection, Double Insulation Protection Level, Spare 5.1 Test Ring, to detect Self Precision, 0.01 High Accuracy for low resistance measurement, Data Logging up to 99 groups, Alarm Threshold setting from 1 to 100, Leakage Current measurement from 0.1mA to 20A..

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurable Earth resistance range - Auto ranging
  • 2-pole method for resistance measurement - YES
  • 3-pole method for resistance measurement - NO
  • Number of the stakes - 4 NOS.
  • Diameter of the Stakes - 1 cm
Other Specifications Download Specification
Display Type 3 digit LCD display
Measurable Earth Resistance Range Auto ranging
2-pole Method For Resistance Measurement YES
3-pole Method For Resistance Measurement NO
4-pole Method For Resistance Measurement YES
Number Of The Stakes 4 NOS.
Material Of The Stakes Metal
Length Of The Stakes 45 cm
Diameter Of The Stakes 1 cm
Number Of The Test Leads 4 Nos.
Length Of The Test Leads 10,20,30,40 cm
No. Of Test Leads With Clamps 4 Nos.
Length Of Test Leads With Clamps 10,20,30,40 cm
Measuring Range1 For Earth Resistance 0.010ohm - 0.099 ohm Ohms
Measuring Range2 For Earth Resistance 0.10 ohm - 0.99ohm Ohms
Measuring Range3 For Earth Resistance 1.0 ohm- 49.9ohm Ohms
Measuring Range4 For Earth Resistance 50.0ohm - 99.5ohm Ohms
Measuring Range5 For Earth Resistance 100ohm - 199ohm Ohms
Measuring Range6 For Earth Resistance 200ohm- 395ohm Ohms
Measuring Range7 For Earth Resistance 400ohm - 590ohm Ohms
Measurable Earth Resistance Resolution For Range1 0.001ohm Ohms
Measurable Earth Resistance Resolution For Range2 0.01ohm Ohms
Measurable Earth Resistance Resolution For Range3 0.1ohm Ohms
Measurable Earth Resistance Resolution For Range4 0.5ohm Ohms
Measurable Earth Resistance Resolution For Range5 1ohm Ohms
Measurable Earth Resistance Resolution For Range6 5ohm Ohms
Measurable Earth Resistance Resolution For Range7 10ohm Ohms
Measurable Earth Resistance Accuracy For Range1 1+0.01ohm ±% reading ± digits
Measurable Earth Resistance Accuracy For Range2 1+0.01ohm ±% reading ± digits
Measurable Earth Resistance Accuracy For Range3 1.5+0.1ohm ±% reading ± digits
Measurable Earth Resistance Accuracy For Range4 2+0.5ohm ±% reading ± digits
Measurable Earth Resistance Accuracy For Range5 3+1ohm ±% reading ± digits
Measurable Earth Resistance Accuracy For Range6 6+5ohm ±% reading ± digits
Measurable Earth Resistance Accuracy For Range7 10+10ohm ±% reading ± digits
Stakeless Test(Clamp On) yes
Facility To Measure Earth Voltage Available
If Yes,Measurable Earth Voltage Range 230 Volts
If Yes,Measurable Earth Voltage Accuracy 0.1 %
Minimum Open Circuit Output Voltage 36 Volts
Low Battery Indication Available
Over Range Indication Available
If Yes,Measurable Earth Voltage Resolution 2 Volts
Internal Memory 99 sets
Type Of Battery Used In The Power Supply 1.5V (AA) x 4 (Alkaline)
Battery Backup Time 24 Hours
Battery Charger Provided With The Meter. Yes
Weight Of The Tester 1250 grams
Dimensions(LXWXH) 28.5x8.5x6.6 cmXcmXcm
Provision For External SD Card No
Interface No
Operating Temperature Range 0-55 degree celsius
Operating Humidity Range 95 %
All Connecting Cables And Accessories To Be Supplied Along With The Tester. Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. Resistance Calibration Plate x 1, Battery 1.5V (AA) x 4 (Installed), User Manual x 1, Carry Bag x 1
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. Yes
Type Test Report No. 52314
TTC Report Date 02.05.2017
Name Of Lab Human Lab
Address Of Lab Uttrakhand

Price Dekho Price Dekho Price List in india