× All the transactions performed on 2.0 is available here. To access Market click "Home".

thermal imager fluke tis40 with 02 years warranty (fluke)(thermal imager fluke tis40 with 02 years warranty)

` 240,000.00

  • MRP: `269345.00

Fluke TiS40 find problems faster in industrial applications with the TiS40 fixed focus infrared camera -- 160x120 resolution.See the detail with a DS of 2571.Capture all the details you need to quickly analyze infrared images with blending and picture-in picture mode - IR-Fusion technology.Clearly see what you are inspecting with a 3.5 inch, 320x240 LCD screen - 33 more viewing area compared to a 3.0 inch LCD screen. Store thousands of images with the internal 4 GB memory.Additional storage and easy image transfer with optional 4 GB micro SD card.Document critical information with your infrared image using voice annotation. Prevent unexpected power loss with the pop in/pop out replaceable smart batteries with a LED charge level indicator. Quality images - 160x120 resolution 19,200 pixels.DS of 2571.Temperature measurement range -20 C to 350 C -4 F to 662 F.Find problems fast with exclusive IR-Fusion Blending and PIP mode capture the details you need to analyze problems and clearly.

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Detector Resolution (min.) - 19,000 Pixels
  • Temperature Range of Objects (Degree Celsius) - -20 to +350 °C
  • Temperature measuring accuracy of reading (or better) - 2.0 % °C
  • Colour LCD Display - N 8.75 cm
  • Thermal sensitivity (NETD) - N 0.1 °C
Other Specifications Download Specification
Type Hand held
Detector Resolution (min.) 19,000 Pixels
Temperature Range Of Objects (Degree Celsius) -20 to +350 °C
Temperature Measuring Accuracy Of Reading (or Better) 2.0 % °C
Minimum Focus Distance N 20 cm
Colour LCD Display N 8.75 cm
Image Capture Frequency/ Frame Rate N 9 Hz
Image Detector Type Uncooled focal plane array (FPA)Vox/ Asi/BST/Silicon
Thermal Sensitivity (NETD) N 0.1 °C
Submit OEM Certificate Or Certificate From Detector Manufacturer For Thermal Sensitivity (NETD ) Yes
Infrared Spectral Band (or Better Coverage Range.) 8 N 14 um
Detector Resolution N 14000 Pixels
Image Palettes N 10
Image Capture, Review And Save Mechanism One handed image capture, review and save capability
Storage Medium:- Mini SD Card/SD Memory Card/ USB Stick Of 2 GB (min.) Internal 4 GB Memory And 4 GB Removable Micro SD Card
File Formats ( JPEG Format Or Enhanced Format ) Fully-Radiometric (.Is2) Or Non-Radiometric (.Bmp, .Jpg) Files
Built-in Digital Camera/ Visual Camera Resolution N 1 Mpixels
Horizental Field Of View Of Standard Lens N 20 Degree
Vertical Field Of View Of Standard Lens N 14 Degree
Horizental Field Of View Of Telephoto Lens No Degree
Vertical Field Of View Of Telephoto Lens No Degree
IFOV Of Standard Lens N 4 mRad
IFOV Of Telephoto Lens No mRad
IFOV Of (Spatial Resolution) NA mRad
User Selectable Emissivity Setting/correction 0.01 N 1
Details Of Operating Functions Capture Image ,menu operated
Operating Temperature ( 0 To 50 Degree Celsius) -10 C To +50 C °C
Control And Adjustments:- The Set Up Menu Should Provide The Facility For The Adjustment/ Selection Of The Time/date Etc. YES
Software:- With Compatible Software And Hardware For Downloading On PC With Windows(Latest) YES
Image Output:- Image Shall Be Able To Be Viewed On PC Or Readable Through Mini SD Card/SD Memory Card/USB Stick Storage Medium YES
Battery Back Up 3hrs Min With Built-in Suitable Charger Or Charger Separately Provided Four+ hours, One lithium ion smart battery pack with five-segment LED display to show charge level hrs
Details Of AC Battery Charging Battery charging system In-imager charging (optional external charger sold separately)
Power Management:- Automatic Shut Down /User Selectable YES
UL Or CE Certificate For Safety YES
Size/ Dimension 26.7 x 10.1 x 14.5 cm
Weight (including Batteries) 0.72 kg
IP Protection (IP 54 Or Better) IP 54
Focus Auto
Interface USB & Wireless
Cost Of Calibration Beyond Warranty Yes
Details Of Voice Annotation (if Any, Not Mandatory) Voice annotation Yes, Bluetooth Headset (sold separately - where available)
Thermal Imagers Are Meant For Preventive Maintenance Purpose Such As Detecting Heat Build Up On Bus Bars, Bus Ducts And Isolators Etc, Heat Generation Detection Of Sub Stations And Control Panels Of HT And LT Lines, Scanning Of Bushing Of Transformers, Scanning Of Circuit Breakers, Scanning Of Joints In 25KV/33KV Overhead Equipments. Scanning Of All Types Of Rotating Machines, Firefighting Help, Building Diagnostics Etc. Yes
Submit Calculation, Showing Minimum Size Of Object, Which Thermal Profile Can Be Scanned By Imager Within Specified Limit Of Accuracy From Maximum Distance To Have First Hand Information With Respect To Its Utility From User's Point Of View. Yes
Software Along With The Equipment License Free Software Downloadable From Website
Adequate Facility For Verification Of Features (excluding IP Protection)of System. Yes
Availability Of The Test Report From Central Govt./ NABL/ ILAC Acredited Lab As Per Doc Correction Slip No. 38 Dtd 18/12/12 Yes
Test Report No., Date Of Test Report Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence For "one Sample Of Each Type/range" Of Thermal Imager. 019
Name Of Lab FLUKE
Address Of Lab USA
Type Test Reports Shall Consist Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences; A. Dry Heat Test (For 16 Hrs At A Temp. Of 55 Degree C In Accordance With IS: 9000/part-3/section-5/1977) (reaffirmed In 2004). B. Cold Test(For 4 Hrs At A Temp. Of -20 Degree C In Accordance With IS: 9000/part-2/section-4/1977 (reaffirmed In 2004). C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1991 (reaffirmed In 2004). Yes
After Environmental Test Sequence As Above And A Recovery Period Of Two Hours,the Equipment Shall Be Checked For Complete Parameters, Excluding IP Protection. Yes
Type Test Reports Shall Consist Of Verification Of All The Features & Functional Parameters &Operating Temperature Tests Sequences; A. The Equipment Shall Be Kept At Zero Deg Celsius For At Least 2 Hours And Measurement Of Object Temperature Shall Be Done To Cover The Entire Temperature Range Specified. B. The Equipment Shall Be Kept At 50 Deg Celsius For At Least 4 Hours And Measurement Of Temperature Shall Be Done To Cover The Entire Temperature Range Specified. C. Drop Test Of Unpacked Thermal Imager From A Height Of 2m. D. IP Protection Test. (Test Method Shall Be As Per Relevant IS: 9000 Series Of Specification) Yes
Availability Of Master Calibrator And Source To Verify The Calibration Of The Instrument On 10% Samples. Yes
Facility Of Environmental Chamber Of Temperature Range 0 To 50 Deg Celsius Or Better To Assess The Operation Of The Equipment In Operating Condition Yes
Availability Of Facility For Verificaion Of All Features & Functional Performance Of The Equipment Except IP Protection On 10% Samples. Yes
Furnished Optical Calculation To Have Idea About Distance To Spot Size Ratio. Yes
Instructions To Maintain Safe Distance From Heated / Live Objects While Capturing The Image. Yes
The Infrared Imaging System Shall Be A Single Unit Suitable For Hand Held Operation Yes
The System Shall Be Capable Of Working In Open Environment And Shall Not Use Any Cooling System Either Internally Or Externally Yes
The Accessories Shall Include One Sets Of Spare Rechargeable Batteries, AC Power Adapter, Battery Charger, Carrying Case, User Manual And Software Installation CD And Any Other Application S/W That May Be Essential To Make The System Complete In All Respect. Yes
In Typical Ambient Environments, When The Cameras On/off Switch Is Activated To Apply Power To The Camera, The Camera Shall Render A Usable Thermal Image In One Minute Or Less. Yes
Camera Shall Not Incorporate A Sleep Mode That Turns-off The Cameras Internal LCD Display While The Camera Is "ON". Yes
The Camera Shall Incorporate An On-screen Battery Level Indicator Yes
The Camera Shall Incorporate An Automatic Active Temperature Stabilization System By Use Of Suitable Method. When The Cameras Electronics Heat-up To A Predetermined Critical Temperature, The Temperature Stabilization System Automatically Activates To Dissipate Heat From The Electronics And Move The Heat Into A Heat Sink Or Camera Shall Be With Uncooled Microbolometer (OEM Certificate Shall Be Furnished To This Effect) Yes
The Camera Shall Incorporate Through-the-lens Direct Temperature Measurement Capability That Measures Relative Surface Temperature Readings. The Direct Temperature Measurement Readings Shall Be Displayed, In Numerical Form. Yes
The Camera Shall Be Fitted With Li Ion Or Better Chemistry Type Rechargeable Batteries Yes