× All the transactions performed on 2.0 is available here. To access Market click "Home".

true rms digital insulation multimeter (kusam meco)(km 878)

` 29,470.00

  • MRP: `38800.00

VFD V Hz readings. Auto ranging. LOCK-Test mode for Insulation Resistance Earth Continuity Test. Beep Jack audible visible input warning. Remote Probe for insulation Resistance Earth Continuity Test..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function Yes
Data Logging more than 99 locations
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range -10C......40C Degree C
Operating Humidity (RH) 80 %
Power Requirements Battery Operated
Type Of Battery Four Alkaline AA batteries
PC Interface Available
Standard Accessories Supplied With The Equipment Test probe pair, BRP21S2-C Remote probe, Alligator clip pair, Holster, User manual & Carrying Case.
Dimensions (H X W X L) 208(L) X 103(W) X 64.5(H) mm with holster mm x mm x
Weight 635 gm with holster. gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 34546789687
Test Report Date 1/11/17
Name Of The Lab kusam meco
Warranty 3

Price Dekho Price Dekho Price List in india