DC REGULATED POWER SUPPLY are constant Voltage, Current Limit Type supplies have high regulation for Load Line Voltage Variation. The Supply can be use in independent and tracking mode. The Supply are protected against short circuit, over load. The output, current can be limited to any value from 0 to maximum. SPECIFICATIONOutput Voltage DC0 - 30V Coarse and fine controlOutput Current 2 A Max V I Indication 3 Digit 7 Segment display for Voltage and currentAccuracy 1 1 digitLine Regulation 10 Mains 1 10mVLoad Regulation 1 10mVRipple Noise Voltage 1 mV rmsCurrent LimitadjustableInternal Resistance 10MohmsTemp. Coefficient 0.05 5 mV/0 CRecovery Time 50 usecProtection available against overload and short circuit.Power Supply 230 V AC 10 50Hz.
Other Specifications Download Specification | |
---|---|
DC Voltage Output Rating | 0 to 30 Volt |
DC Current Output Rating | 0 to 4 Ampere |
Maximum Power | 120 Watt |
Load Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 2 mV |
Load Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 1.5 mA |
Line Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 1 mV |
Line Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 0.1 mA |
Over Voltage Protection Accuracy | +- 0.5 + 0.5 V |
Over Voltage Protection Response Time | less than 10 milli sec |
Ripple And Noise Voltage (20 Hz To 20 MHz) | less than 1 mVrms less than 4 mVpp |
Ripple And Noise Current (20 Hz To 20 MHz) | less than 4 mArms |
Readback Voltage Accuracy | 0.05 + 10 mV |
Readback Current Accuracy | 0.15 + 4 mA |
Readback Voltage Resolution | 1 mV |
Readback Current Resolution | 0.1 mA |
Operating Temperature | 40 Degree C |
Gperating Humidity (RH) | 1 % |
PC Interface | USB |
Dimensions | 90X155 mm x mm x |
Weight | GPIB gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | IAS/QMS/B1694 |
Test Report Date | 24/11/2017 |
Name Of The Lab | CCPL |
Warranty | 1 Year |