Blockage-free submersible pump with maximum solid passage of 80 mm, impeller made of corrosion-free, wear resistant, self-cleaning aluminum bronze, housing made of saltwater-proof aluminum alloy, stainless steel carrying frame with 4 folding handles, abseiling eyelet, dry-run and continuous operation suitable double mechanical seal, CEE motor protection plug 400V/16A/IP54/5-pin with rotating field control unit and phase inverter, 20 m heavy duty H07RN8-F power cable 4G1,5 in signal colour yellow, cable inlet with stainless steel bend protection, A-Storz coupling made of aluminum on inlet and outlet side, A-Storz intake socket and flat intake socket made of PE for low level pumping down to a few millimeters depth,coupling wrench, with English operating manual . Operating voltage U3P 400 V Frequency f 50 Hz Power consumption P1 3,2 kW Nominal current I7,3 A Protection class IP68 Max. capacity2500 l/min Dimensions LxWxH500x395x435 mm Weight 53 kg.
Other Specifications Download Specification | |
---|---|
Indian Standrad For Code Of Acceptance Tests For Centrifugal, Mixed Flow And Axial Pumps. | IS:9137 latest Amendment |
ISI Marked | No |
CM/L No. And Date (If Yes) , Otherwise Put NA | NA |
Make Of Pump | Spechtenhauser |
Model No. Of Pump | Chiemsee A |
Capacity (Rate Of Flow) | 150 m³/hr |
If Other Rate Of Flow Please Specify In M3/h | 150 m3/h |
Total Head (min.) Corrsponding To Capacity And Speed | 14 metres |
Speed In RPM | 1400 rpm |
Pump Efficiency At Duty Point Corrsponding To Capacity And Speed ( Water Delivered / Pump Input ) | 75 % |
Power Input To Pump At Duty Point | 3.2 Kilowatt |
NET Positive Suction Head(NPSH) | 5 metre |
Service/Duty | Continuous |
Temperature Must Be Upto 40 Degree | Yes |
Location | Outdoor |
Casing | Cast Iron of Grade FG200 of IS 210 |
Impeller | Stainless Steel of Grade 20Cr13 of IS 6603 |
Casing And Impeller Wearing Ring If Provided Otherwise Put NA | BRASS |
Shaft : | Stainless Steel |
Gland Packing | Non Asbestor |
Type : | Air cooled |
No. Of Cylinder: | 1 No |
Blade Material | Aluminium |
Lub. Oil Consumption(g/k Wh): | 10 (g/k Wh) |
Sleeve : | Brass |
Bracket: | Stainless Steel |
Suction Flange: | Stainless Steel |
Volute Casing | Stainless Steel |
Gland Packing Set : | Brass |
Delivery Flange: | Mild Steel |
Rotation: Clock Wise While Facing The Flywheel End | Yes |
Complete Unit Including Pump & Engine Duly Coupled Along With Auto Prime System, Fuel Tank Etc Shall Be Mounted On A Two Wheeled Trolley For Easy Transportability,The Trolley Shall Be Equipped With Leaf Springs For Suspension, Support For Rear End And Towing Bar, Parking Breaks Etc And The Trolley Must Have Minimum Ground Clearance Of 300 Mm, Below Leaf Spring. | Yes |
Material Of Trolley | MS fabricated |
.Type Of Pump: | Back pull out |
.Fuel Supply: | Fuel pump by gravity feed through tank |
.Starting : | battery start |
Suction And Delivery Pipe Dimensions ( Mm X Mm) | 100 x 100 mm mmXmm |
Fuel Tank Capacity For Min.24 Hours Continous Running At Full Load | 10 litres |
All Rotating Parts Be Dynamically Balanced For Longer Bearing Life And Vibration Free Smooth And Silent Operation | Yes |
Supply Of Auto Prime, Horizontal, End Suction, Centrifugal Type Pumping Unit Capable Handling Floating Material/soft Solids Like Wooden Pieces , Muddy Water, Etc. | Yes |
The Pump Shall Be Capable Of Developing Required Head At Rated Capacity For Continuous Outdoor Operation. External Conditions Like Rain, Snow And Humidity Should Not Affect Pumping Operation. | Yes |
The Shut Off Head Of The Pump Shall Not Less Than 12% Of Head At Rated Capacity For 3 Cusec And 5 Cusec Pumps Having 10 Mtrs. As Duly Point Head. | Yes |
The Pump Should Be Capable Of Starting Without External Priming And Should Be Capable Of Operation With Least Human Intervention. | Yes |
The Pump Must Have Non-overloading Characteristics And The Prime Mover I.e. Engine Shall Not Get Overloaded In The Entire Range Of Operation | Yes |
Engine Capacity | 4.29 HP |
Engine Make | Spechtenhauser |
The Engine Shall Be Vertical, Inline, Diesel Engine Capable Of Continuous Operation And Must Be Equipped With 12 Volt Starter And Alternator, Control Panel, Wiring Harness For Panel Fuel Pipes And Suitable Battery. | Yes |
One Number Suitable Size Suction Strainer And Non Return Value To Be Supplied With Each Pump. | Yes |
Diesel Engine Be Closed Coupled And Mounted On A Base Plate Robust | Yes |
Material Of Base Plate On Which Engine Is Mounted | Mild Steel |
Make Of Engine Control Panel | OTHERS |
If Others , Please Specify The Make For Engine Control | Spechtenhauser |
Engine Control Panel With Following Items: I. Engine START Switch Ii. Engine Oil Pressure Meter Iii. Engine Temperature Meter IV. Ampere Meter V.Emergency Engine Stop Switch Engine Oil Pressure Meter Vi. Engine Hour Meter Vii.Fuel Indication Meter Viii. RPM Meter | Yes |
No. Of Stages | 1 |
Dimension Of Pump Set ( L X B X H ) | 500x395x435 mm mmXmmXmm |
Weight Of Pump Set | 53 Kg |
Minimum Submerge | 0.10 metres |
Safety Controls To Shutdown The Engine In The Event Of Low Lub Oil Pressure Or High Cylinder Head Temperature In Case Of Air Cooled Engines | Yes |
Exhaust Silencer Of Residential Type Application | Yes |
12 V Starting System Complete With Starter Motor, Charging Alternator And Cutout | Yes |
Standard Set Of Tools Consisting Of Set Of 3 Spanners ,one Screw Driver ,one Standard Plier And One Nose Plier Of Appropriate Engine Size Shall Be Provided To The Consignee Along With , Free Of Cost For Each Of Pump Set. | Yes |
Availability Of Type Test Report For Conformity IS As Per IS:10,001latest/IS 11170latest/IS:7347latest ForEngines,to IS:11501 Latest And IS:9137 Latest For Pumps And Other Parameters To Specification From Any ILAC/NABL Accredited/Central Gov. LAB . | Yes |
Test Cetificate No. | 2006/42/EC |
Test Report Date | 20122016 |
Name And Address Of The Lab Where Test Conducted. | Hauptsitz: Gewerbestr. 3 86875 Waal |
Warranty | 2 |