Compact benchtop casting machine with very high-performance induction heating guarantees short melting cycles, minimises oxidation and thus facilitates subsequent finishing Compact dimensions and design give the new Fornax T a very small footprint Integrated power cooling enables more than 50 casts in a row, even with high ambient temperatures High output reserves with low power consumption of just 16 amps Casting temperature of up to 1550C ideal for all commercially available dental alloys except titanium The user-friendly operating panel provides information on all parameters and gives quick and easy access to all major functions Very quick adjustment to different casting mould sizes by means of a simple mechanism ensures fast working.
Other Specifications Download Specification | |
---|---|
DC Voltage Output Rating | 0 to 30 Volt |
DC Current Output Rating | 0 to 4 Ampere |
Maximum Power | 120 Watt |
Load Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 2 mV |
Load Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 1.5 mA |
Line Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 1 mV |
Line Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 0.1 mA |
Over Voltage Protection Accuracy | +- 0.5 + 0.5 V |
Over Voltage Protection Response Time | less than 10 milli sec |
Ripple And Noise Voltage (20 Hz To 20 MHz) | less than 1 mVrms less than 4 mVpp |
Ripple And Noise Current (20 Hz To 20 MHz) | less than 4 mArms |
Readback Voltage Accuracy | 0.05 + 10 mV |
Readback Current Accuracy | 0.15 + 4 mA |
Readback Voltage Resolution | 1 mV |
Readback Current Resolution | 0.1 mA |
Operating Temperature | 65 Degree C |
Gperating Humidity (RH) | 85 % |
PC Interface | USB |
Dimensions | 350x356x250 mm x mm x |
Weight | GPIB gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 21454 |
Test Report Date | 21.05.2017 |
Name Of The Lab | Star Labs |
Warranty | 1 Year |