× All the transactions performed on 2.0 is available here. To access Market click "Home".

Oscilloscope (SOHAM)(SI-OSC-30)

` 88,000.00

  • MRP: `98000.00

Oscilloscope.

  • Availability: 500 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Non -Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - NA ns
Other Specifications Download Specification
Type Analog
Operating System Non -Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width NA ns
Memory Upgradability No
Segmented Memory Feature Availability No
Vertical Sensitivity 2mV/Div to 5 V/Div
Vertical Resolution NA bits
Coupling AC, DC and Ground
Time Base Range 0.5uSec/cm to 0.2sec/cm
Trigger Types Automatic and Normal
Measurements NA
Frequency Analysis Feature No
In-built Frequency Counter Yes
In-built Function Generator No
Acquisition Modes NA
Display Type Monochrome
Display Size 14 CM
I/O Interface USB Interface
Standard Accessories To Be Supplied One BNC to BNC, One BNC to Crocodile Probe, Power Cord, Manual and Factory Test Certificate
Operating Temperature Range 5 to 45 Degree Degree C
Operating Humidity (RH) 95 RH at 30 Degree %
Power Supply 230V +- 10 , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. PICL/QMS/0916/5004
Test Report Date 12/01/2017
Name Of The Lab AIAB PROGRESSIVE LAB
Warranty 1 Year
Real Time Bandwidth 30 MHz
Record Length Per Analog Channel Simultaneously NA Mega Point
Sample Rate Per Analog Channel Simultaneously NA GS/sec
Waveform Update Rate NA Waveforms/
Time Base Accuracy 0.05 PPM

Price Dekho Price Dekho Price List in india