UCS C240 M5 12 LFF 2 rear drives w/o CPU,mem,HD,PCIe,PS,SNTC 8X5XNBD UCS C240 M5 12 LFF 3 rear drives w/o CPU,mem.2.2 GHz 4114/85W 10C/13.75MB Cache/DDR4 2400MHz,32GB DDR4-2666-MHz RDIMM/PC4-21300/dual rank/x4/1.2v,Riser 1 incl 3 PCIe slots x8, x16, x8 slot 3 req CPU2.Cisco UCS 1600W AC Power Supply for Rack Server.AC Power Cord - 250V, 10A , India.Ball Bearing Rail Kit for C220 C240 M4 M5 rack servers.KVM local IO cable for UCS servers console port.IMC SW Recommended latest release for C-Series Servers.Heat sink for UCS C240 M5 rack servers 150W CPUs below.C240 M5 PCIe Riser Blanking Panel.C240 Rear UCSC-RAID-M5 SAS cbl1kitinclfan,bkplnforSFFLFF.Super Cap cable for UCSC-RAID-M5 on C240 M5 Servers.Super Cap for UCSC-RAID-M5, UCSC-MRAID1GB-KIT.Cisco 12G Modular RAID controller with 2GB cache.10TB 6G SATA 7.2K RPM LFF HDD.240GB 2.5 inch Enterprise Value 6G SATA SSD.Cisco ONE Data Center Compute Opt Out Option..
Other Specifications Download Specification | |
---|---|
Processor Configuration | E5-2640 v4, 10 core, 2.40GHz with 25 MB smart cache memory, 90 watt |
Form Factor | Rack |
Processor Make | Intel |
Max. Number Of Sockets Available On Chipset | Dual 2-socket |
Max. Number Of Sockets Populated With Processor | 1 |
No. Of Processor | 1 |
Number Of Core Per Processor | 10 |
Chipset Compatible With CPU | Intel C610 chipset |
Motherboard (OEMcompatible With CPU) | Yes |
PCI Slots (Express Gen 3.0 Min.) | Dual x8 PCIe half-height |
Max Nos Of PCI Lanes | 48 |
Memory ( DDR4 RAM Min.) | 512 GB of DDR3 or DDR4 memory per server node GB |
DDR4 RAM Upgradable Upto (Minimum) | 4 TB GB |
DIMM Slots (Minumum) | 8 No. |
Hard Disk Drive Capacity | 600 TB GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | 7.2K RPM |
RAID Controller Caches | 4 Gbps MB |
RAID Controller | LSI 3316 ROC controller |
RAID Controller Ports | 12 Gbps SAS |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
Bays (min. 2 Internal Or More Hot Plug) | 2 |
USB Ports (version 2.0/3.0) | USB 3.0 |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
DVD ROM (or Better) | 8x or better |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Not-Available |
FC HBA Dual Port Card Speed | N/A |
Power Management | Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected, automatic server reboot. |
Redundant Power Supply | Yes |
Redundant Fan | Yes |
Server Scalability To Be Achived Within The Box & Without Adding Nodes | Yes |
Avaialbiklity Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | Yes |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | Yes |
Test Report No. & Date | Yes - Tested for worlwide Environment and Saftey standards like EN60950-1:2006+A11+A1+A12+A2 and EN50581:2012 |
Name & Address Of Lab | Test Reported available from International acclaimed labs |
BIS Registration No. Under CRS Of Deity | Test Reported available from International acclaimed labs |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | spec Intratebase 2006: 896 Specfprate2006: 825 |
Declare Max. Power Consumption Of The System | 2010W |
Availability Of Documentary Evidence In Support Of Model Quoted In Commersial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | SPEC.org |
Server Main Supply | 230V, 10,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |
Warranty | 3 years |