fluke 287 true-rms electronics logging multimeter with trendcapture (fluke)(fluke 287 true -rms dmm)

` 41,526.00

  • MRP: `65254.00

True RMS Electronics Logging Multimeter with Trend Capture, Fluke 287 packs more accuracy and convenience into a handheld multi meter than ever before, putting more problem solving power in your hands. It is the ultimate handheld tool for demanding applications that require high-precision.Store up to 15,000 recorded events Large 50,000 count, 1/4 VGA display with white backlight. Multiple sets of measurement information can simultaneously be displayed at the same time,Peak capture to record transients as fast as 250 micro second,Real Time Clock for automatic time stamping of saved readings, CAT III 1000 V / CAT IV 600 V safety rated, Relative mode to remove test lead resistance from low ohms or capacitance measurements, Min/Max/Average with Time Stamp to record signal fluctuations, 0.025 percent Basic DC accuracy, 100 kHz ac bandwidth, Temperature function, Limited lifetime warranty,....

  • Availability: 6 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 4.5 Digit
  • Measurement Type - True RMS
  • Count - 50000
  • AC Voltage Measurement Accuracy - 0.5 %
  • AC Current Measurement - 10 Ampere
Other Specifications Download Specification
Type Hand Held
Display 4.5 Digit
Measurement Type True RMS
Count 50000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.5 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy .05 %
AC Current Measurement 10 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 10 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 100 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 300 Kilo Hertz
Frequency Measurement Accuracy 0.1 %
Capacitance Mreasurement Range 1 to 100 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -50 to 1000 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Available
If Data Logging Feature Is Available, Internal Memory min. 2000 points 500 readings
Computer Interface Alongwith Software Available
True RMS AC Voltage Band Width 100
Safety Rating Category IV 600 V of IEC 61010
Overload Protection Through Fuse
Operating Temperature Range -20 °C to +55 °C
Operating Humidity (RH) 0 to 90 (0 °C - 37 °C), 0 to 65 (37 °C - 45 °C), 0 to 45 (45 °C - 55 °C)
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) CSA
If Battery Operated, Type And No. Of Battery 6 AA
Total Voltage Of Battery 9 V
Standard Accessories Supplied With The Equipment Test Leads,alligator clips, 9V Battery, excluding Temperature probe and Manual
Dimensions (H X W X L) 22.2 cm x 10.2 cm x 6 cm mm x mm x mm x mm x
Weight 870.9 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 40100189
Test Report Date 28/09/2017
Name Of The Lab Fluke ISO 9001 Certified Lab, USA
Warranty 5 Year