× All the transactions performed on 2.0 is available here. To access Market click "Home".

0 - 2mhz function generator (tatame)(tatame function generator 2 mhz)

` 10,999.00

  • MRP: `12500.00

5 digit LED display including 3 digits for voltage - - Frequency and amplitude display simultaneously - - Output waveforms sine wave, square wave and triangle wave - - Frequency of output signal 0.2Hz 2MHz - - Duty cycle adjustable 20 80 - - Width of output signal adjustable continuously - - Amplitude without attenuation 0.9V 10V - - Amplitude with -20dB attenuation 100mV 1V - - Amplitude with -40dB attenuation 10mV 100mV.

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • No. of Channels - 1
  • Standard Waveforms - Sine, Square, Pulse, Ramp, Noise, Sin(x)/x, Exponential rise/fall, Gussian, DC Offset
  • Band Width of Arbitrary Waveform Generator - 10 mHz to 5 MHz
  • Record Length of Arbitrary Waveform Generator - 16 Kilo Points
  • Amplitude Range (at 50 ohm impedance) - 10 mV to 10 V pp
Other Specifications Download Specification
Frequency Bandwidth (Sine Wave) 10 mHz to 25 MHz
No. Of Channels 1
Standard Waveforms Sine, Square, Pulse, Ramp, Noise, Sin(x)/x, Exponential rise/fall, Gussian, DC Offset
Band Width Of Arbitrary Waveform Generator 10 mHz to 5 MHz
Sample Rate Of Arbitrary Waveform Generator 50 Mega Samples/sec
Record Length Of Arbitrary Waveform Generator 16 Kilo Points
Waveform Memory Of Arbitrary Waveform Generator 4 Waveforms
Vertical Resolution (Minimum) 12 Bits
Amplitude Range (at 50 Ohm Impedance) 10 mV to 10 V pp
Modulation AM, FM, PM, FSK, Burst, PWM
Interface USB
Display Colour
Standard Accessories (To Be Supplied) Manual and Powercord
Power Requirements 230 V +/-10 AC, 50 Hz +/- 3
Operating Temperature Range 55 Degree C
Operating Humidity (RH) 75 %
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. (Test Reports Are To Be Furnished When Demanded By Buyer)" Yes
Test Report No. ETDC/INSP/2016/165
Test Report Date 07/05/2016
Name Of The Lab Electronic Test & Development Centre, Indore
Warranty 3 Years

Price Dekho Price Dekho Price List in india