The fire gloves produced by our company are used to protect the opponents and wrist during fire fighting, so as to prevent cuts and burns. Style refers to split open, inside and outside four layers of flames retardant resistance. Five fingers are separated, four layers inside and outside the structure the outer layer adopts NomexIIIA Aramid fabric, and in the key place with cattle leather reinforcement, wear, puncture, permanent flame retardant function. The waterproof layer TPU breathable film, has good waterproof performance, breathable function heat insulation layer adopts Aramid fibre insulation, flame retardant, heat radiation and other functions lining with Aramid materials with flame retardant, comfortable performance,. This product is a special gloves designed and manufactured according to the characteristics of fire fighting operation. It has advantage of low preheating, low shrinkage, soft and comfortable wear, strong wear resistance, anti-static, heat insulation..
Other Specifications Download Specification | |
---|---|
Conformity To EN Standard | EN 659:2008 for Fireman Gloves |
Item (s) (Components) | Fireman Gloves |
Fire Proximity Suit (Coat & Trouser) Size | Medium (M) ( Suitable for person of height 158-164 cm, Chest Girth 88-96 cm, Waist Girth 84-92 cm) |
Suit Colour | Navy Blue |
"Suit Fabric:- The Fabric Namely Nomex/Kevlar Or Equivalent Shall Be Used For Manufacture Of The Suit. The Garment Manufactures Have To Furnish The Genuinity Certificate/test Certificates Issued By M/s. DuPont ( Or ) The Manufacturer Of The Fibre For The Fabric. " | Yes |
"The Generic Fibre Of Suit Shall Be As Below Outer Shell/ Layer Contains Fibre Composition Of Para Aramide + Meta- Aramide + 2% Antistatic Etc. GSM 190 ( Minimum ), (OR) Para Amarmide + Polybenzimdiazole + 2% Anti Static GSM 190 ( Minimum) Middle Layer Contains Fibre Composition Of:- Meta Aramide + Para Aramide + PTFE Bicomponent Membrane, Lining Fabric Contains Fibre Composition Of:-Blend Of Meta Aramide ( Or ) Blend Of Modarylic. " | Yes |
Fireman Helmet (Type B) Sizes Shall Be As Per Clause 5.1.2 Of Helment Adjustment Of EN:443-2008 | NA |
Fireman Gloves Size | 7 |
Fireman Boot Size | 7 |
Firehood Shall Be Manufactured In Various Sizes Or Be Sufficiently Elastic To Be Compitable With Various Head Sizes And Shape | NA |
"All The Items (components) Should Be Approved To Relevant EN Standards And Should Be Supported With Both EC Type Examination Certificate"" As Per Article 10 & ""EC Quality System Certificate"" As Per Article 11 A Or 11B As Per EEC Guidelines Individually. Country Of Origine, The Place Of Production With Complete Address Shall Be Mentioned In The Quality Assessment Certificate As Per Article 11B." | Yes |
"Labelling:-Each Set Must Be Having LABLE Attached And Instruction On The Label. Improper Process Could Modify The Clothing Features And Protective Levels, Keep Clothing Dry And Clean In Suitable Place At Ambient Temperature And Humidity ,Do Not Expose It To Heat Or Cold Surface And To Repair The Clothing We Recommend To Use Only Materials Like The Ones Used For The Manufacturing Of The Clothing . No Other Materials Must Be Used And Repairs Must Be Carried Out Only By An Experienced Staff Or Directly By The Manufacturer .The Clothing Has Been Planned With High Quality Components . In Spite Of This Protective Features Can Be Subject To Degradation In The Long Run As A Result Of The Condition Of Working Place. Therefore It Is Not Possible To Fix The Durability Of The Clothing But In Any Case, Following Exposure To A Risk That Might Damage Whatever Components, The Time Frame Is Undecided. " | Yes |
Technical Manual Comprising Of Servicing Details Shall Be Supplied With System. | Yes |
"The Firm Shall Furnish Manufacturers ™ Test Certificate For The Fabric, Major Components And Main Item On The Basis Of The Test Performed On The Representative Samples " | Yes |
"Supplier Has To Educate To End User As Follows:- The Items Are To Be Used At A Close Proximity To The Fire Never Exceeding A Closeness Of More Than 1 Meter From The Fire. They Are NEVER To BE USED For FIRE ENTRY Purpose. How To Use The Fire Suit About Wearing And Removing. How Maintain The Fire Suit. Limitation Of Use Of Fire Suit According To The User Manual Provided Along With The Fire Suit Fire Suit Needs To Be Inspected Every Time After Use To Identify If It Suitable For Deployment. The Reason Is That After Exposure To Every Fire Accident The Fire Fighting Suit May Get Damaged And Hence, This May Be Render The Fire Proximity Suit Unsutiable For Deployment Till It Is Repaired . Wash Care Maintenance Of Fire Suit Is Strongly Recommended. Ideally After Every Six Months The Fire Suits Should Be Sent Back To The Manufacture For Wash Care And Maintenance. This Will Ensure That The Fire Proximity Suits Are Clean And Suitable For Deployment After Exposure To Previous Fire Fighting Activity. The Fire Fighting Suits Normally Are Recommended With A Shelf Life Of 5 Years From The Date Of Manufacture And Ideally Should Be Replaced After This Period. | Yes |
Availability Of Complete & Satisfactory Test Report From Central Govt/ NABL/ ILAC Accredited Laboratory For Individual Components (as Applicable) Conforming To Relevant EN Standard | Yes |
Test Report No. | GA7-2004 |
Test Report Date | 0 |
Name Of Lab Where Test Conducted | 0 |
Availabiility Of CE Certificate For Individual Item (component) Genuinity Of Which To Be Verified From The Certification Agency | Yes |
Copy Of Test Report And Certifications To Be Furnished To The Buyer On Demand | Yes |