X Ray Processing- Dental OPG (GME)(Pantograph Digi)

` 1,665,000.00

  • MRP: `1850000.00

X Ray Processing- Dental OPG Unit Type of EquipmentPantograph Digi-10Power Supply230v /- 10 10 Amp.Column Height230 cmVertical MovementMotor drivenAnode Voltage55 KVP to 85 KVP in step of 1 KVPTube Current10mA fixedX-Ray Tube0.5 mm sq. Fine focusExposure TimeOPG 17 sec. Adult, 14 sec. ChildCEPH 0.2 sec. To 3 sec. TMJ 4 x 4 sec.Film SizeOPG TMJ 6 x 12 10 x 12 CEPH 8 x 10Cassette SizeOPG TMJ Flat 6 x 12 10 x 12 CEPH Flat 8 x 10Safety featuresProvision for Earth Fault, KV Error, Filament Error Thermal ProtectionElectrical Safety ClassificationEN 60601-1 class 1/BDigital Unit.

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • The assembly made up of material non corrosive - Yes
  • Length of Machine - 8 ft
  • Width of Machine - 4 ft
  • Weight (Empty) - 200
  • Auto washer - Yes
Other Specifications Download Specification
Table Top Automatic Medical X Ray Film Processor Machine Yes
The Assembly Made Up Of Material Non Corrosive Yes
Length Of Machine 8 ft
Width Of Machine 4 ft
Height Of Machine 8 ft
Weight (Empty) 200
Auto Developer , Yes
Auto Fixer Yes
Auto Washer Yes
Auto Dryer Yes
Material Of Cabinet ABS Plastic
Rollers Mechanism Motrised
Rollers Material PVC with inner pipes of SS-304 Grade
Minimum Film Size Length X Width 100 x 100
Maximum Film Size Length X Width 356 x 432
Continious Film Roller Transport And Auto Start And Stop Facility Rigid PVC
Processing Time: 90 Sec To 200 Sec In Steps Of Six Second With LED Display Yes
Processing Capacity Of Size 356mm X 432 Mm In 90 Second Mode Yes
Minimum Capacity Of Fixer,Washer And Developer Tank 5
Mimimum Capacity Of Replenishment Developer And Fixer Tank With Overflow Drain Facility 25
Automatic Replenishment Yes
Developer And Fixer Temprature Adjustable Throught Automatic Temprature Controller Yes
Operating Temp Range (28-37 )degree degree
Dryer Temprature(maximum) 70 degree
Power Supply 230 volt A.C
Maximum Power Consumption 1.4 kwh
Water Filter Compatible With Equipment Supplied With Equipment Yes
Manual ,auto Stop With Power Saver/standby Mode Facility Yes
High Voltage Test 1.5 KV For I Minute Yes
Minimum Insulation At 500 V DC AERB
Instruction Manual Supplied With Equipment 1
Chemicals/Materail For Running Equipment For Minimum One Month Manual
Radiology Certificate For Processed Film AERB
Availibility Of Type Test Report For Performance Test AERB Approval
Test Report To Shown To Buyer As And When Required Yes
Test Report Number & Date AERB Approval
Name & Address Of Laboratory Atomic Energy Regulatory Board
Certifiacation TYPE APPROVAL FOR EQUIPMENT