× All the transactions performed on 2.0 is available here. To access Market click "Home".

Product Specifications

Electronic physiogrowth monitoring system Specifications

1. Electronic Physiogrowth Monitoring System
2. Weighing Capacity (Kg)
Must declare
3. Height Measurement by Ultrasonic Sensor
4. Height Measurement upto (cm)
Must declare
5. Least Count
Please define for both weight and height along with units
6. Baby Tray (detachable) Material
May select NA in case of Adults Monitoring System
7. Display Type
Must declare
8. Display Size (cm)
Must declare
9. Keyboard
i.e. 12 keys with keys like tare,enter,zero,on and off etc. please specify like that
10. Battery
Define battery Type, life and its rating
11. Battery Backup (Hours)
It should be greater than or equal to 10 Hours
12. Battery Charging Time (Hours)
It should be less than or equal to 8 Hours
13. Customised Software available with the machine facilitates following automated functions: a) Age calculation b) Real time login status c) Growth Grade calculation as per WHO/IAP formulation d) Beneficiary aligned data for storage and display e) Scroll Back facility to access Beneficiary wise records f ) Nutritional Beneficiary status.
14. Tamper Proof Data Storage
15. Data Storage Capacity (Max.)
i.e. may records 500 health records or any value please define
16. Data Transfer
i.e. By GPRS, encrypted cartridge based, USB Port, RS-232 Port or any other please specify all
17. Environmental Tests Sequences as : a. Dry Heat Test: For 16 hrs at a temp. Of 45 degree C in accordance with IS: 9000/part-3/section-5/1977 (reaffirmed 2007). b. Cold Test: For 4 hrs at a temp. of 0 degree C in accordance with IS: 9000/part-2/section-4/1977(reaffirmed 2007). c. Damp Heat Test: For 2 cycles of 24 hrs each at a temp. 40 degree C & 95% RH in accordance with IS: 9000/part-5/section-1/1981 (reaffirmed 2007).
18. Type tests reports from a Central Govt. lab OR International Laboratory Accreditaion Cooperation (ILAC)or their worldwide affiliated/ recognised labs OR NABL approved lab or from weight and measurments Regional Refernce Standard Laboratory including environmental test sequences showing conformity to the specifications.
19. Name of the Lab
Must Declare
20. Address of the Lab
Must Declare
21. Test Report No. and Date
Must Declare
22. Additional Features
Must Declare
23. Automated BP Monitor Attachment
24. Electronic scale for chest measurement
25. Integrated Prniter
26. Power Requirement
Must declare
27. Power Consumption (Watt)
Must declare
28. Model approval from Department of Weight and Measurements
29. Dimension (mmxmmxmm )
Must declare
30. Overall Weight of the System (Kg)
Must declare
31. Warranty (Year)
It should be greater than or equal to 1