× All the transactions performed on 2.0 is available here. To access Market click "Home".

single phase power quality analyzer (fluke)(fluke-345)

` 198,000.00

  • MRP: `296000.00

Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.Setup and troubleshoot variable frequency drives and UPS systems,Harmonics measurements,Inrush capture,Load studies,AC/DC current,Highest safety rating,Accurate in noisy environments,Data logging,Verify batteries,Troubleshoot harmonics,Inrush current,Easy to use,3-Phase power,View graphs and generate reports, Warranty-01 Year, For Detailed specification please refer Fluke-345 Datasheet.

  • Availability: 4 In Stock
  • Min. Qty. Per Consignee: 1
  • Display type - LCD Backlit
  • Display Mode - 70 mm Diagonal
  • Number of Current Channels - 01 Nos.
  • Facility to Measure RMS Voltage - Available
  • Measurable voltage resolution - 1 mV in 4 V range, 10 mV in 40 V range, 100 mV in 400 V range, 1 V in 750 V range Volts
Other Specifications Download Specification
Type Of Power Analyzer Single phase
Display Type LCD Backlit
Display Mode 70 mm Diagonal
Number Of Current Channels 01 Nos.
Number Of Voltage Channels 01 Nos.
Facility To Measure RMS Voltage Available
Measurable Voltage Range 825 Volts
Measurable Voltage Accuracy V > 1 V: ± 1 % rdg ± 5 digits, V
Measurable Voltage Resolution 1 mV in 4 V range, 10 mV in 40 V range, 100 mV in 400 V range, 1 V in 750 V range Volts
Facility To Measure RMS Current Available
Measurable Current Range 0 to 2000 A dc or 1400 ac rms Ampere
Measurable Current Accuracy I > 10 A: ± 1.5 % rdg ± 5 digits,I
Measurable Current Resolution 10 mA in 40 A range,100 mA in 400 A range,1 A in 2000 A range Ampere
Facility To Measure Active, Reactive And Apparent Power Available
Maximum Power That Can Be Measured 0 to 1650 kW dc or 1200 kW ac KW
Power Accuracy 2.5 % rdg ± 5 digits, W1Ø
Power Resolution 1 VA in 4 kVA,10 VA in 40 kVA,100 VA in 400 kVA 1 kVA in 1200 kVA Watt
Facility To Measure Active, Reactive And Apparent Energy Available
Facility To Measure Sag(dips) And Swell(surge) Available
Facility To Measure Frequency Available
Frequency Range That Can Be Measured 15 Hz to 1 kHz Hz
Facility To Measure Total Harmonic Distortion Available
Accuracy In Measurement Of Total Harmonics Distortion ± 3 % rdg ± 5 digits, ± 5 % rdg ± 5 digits
Resolution In Measurement Of Total Harmonics Distortion 0.1%
Facility To Measure Inter Harmonics Available
Order(n) To Which Facility To Measure Harmonics Available 30
Facility To Measure Power Factor Available
Accuracy In Measurement Of Power Factor ± 3°
Facility To Measure Distortion Factor Available
Accuracy In Measurement Of Distortion Factor ± 3 % rdg ± 5 digits,± 5 % ± 2 digits,± 10 % ± 2 digits
Facility To Measure Ripple Factor Available
Accuracy In Measurement Of Ripple Factor 2 % ≤ RPL
Facility To Measure Voltage And Current Unbalance NA
Facility To Measure Inrush Current Available
Facility To Measure Flicker Available
Facility To Measure Crest Factor Available
Measurable Crest Factor Range 1.1 ≤ CF
Measurable Crest Factor Accuracy 1.1 ≤ CF
Measurable Crest Factor Resolution 0.01%
Screen Memory Available
Data Transfer Software Provided For Analysis On PC Yes
Internal Memory Available MB
Type Of Battery Used Battery type 1.5 V Alkaline
Battery Backup > 10 hours (backlight on full), > 12 hours (backlight reduced) Hours
Power Supply(volts In AC) 230
Weight Of The Analyser 820 Grams
Dimensions(LXWXH) 30.0 X 9.8 X 5.2 cmXcmXcm
Provision For External SD Card No
Operating Temperature Range 0 °C to 50 °C degree celsius
Operating Humidity 80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F) %
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer 345 Power Quality Clamp Meter, Soft carrying case, Power Log software, Test leads, Alligator clips, Test probes, USB cable, International ac adapter / battery eliminator, Printed English language user manual, Multi-language manual CD
Compliance To IEC 61000-4-30 Yes
Category Of Safety Rating Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2
Dry Heat Test As Per IS :9000(Part 3/Section 5) Yes
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) Yes
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) Yes
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. Yes
Type Test Report No. STANDARD
TTC Report Date STANDARD
Name Of Lab STANDARD
Address Of Lab STANDARD
Interface USB

Price Dekho Price Dekho Price List in india