The Keysight Technologies, Inc. N9310A RF Signal Generator covers a frequency range from 9 kHz to 3 GHz. With its low price, reliable performance, and straightforward functionality, its well-suited for start-up RD, service maintenance, manufacturing, and education. Easily perform general purpose testing with a full sweep function. Expand your test with extensive analog and optional IQ modulation. Simpler front panel and remote operation with an intuitive GUI in 11 languages and standard USB connectivity. Obtain reliable results in installation and maintenance, service and repair. Provide essential RF education training. N9310A Signal Generator provides the functionality you need thats just essential for general purpose testing. Step or point swept CW output maximum 1,001 points, Low frequency output, Analog modulation output AM, FM, FM, and pulse modulation, Internal modulation source able to Provide 20 Hz to 80 kHz sine wave for N9310A, Output via the LF output port on the N9310As front panel. Standard 3 Year Warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent..
Other Specifications Download Specification | |
---|---|
Type | RF Signal Generator |
Frequency Range | 9 KHz to 3 GHz |
Frequency Resolution | 0,1 Hz |
Ageing Rate For Reference Frequency (As Declared By OEM) | Less than 2 PPM/Year |
Temperature Stability For Reference Frequency | Less than 2 PPM |
SSB Phase Noise At 1GHz,on 20KHz Offset (dBc/Hz) | less than -95 dBc |
Harmonics At 3 GHz Level At 0 DBm | less than -30 dBc |
Non Harmonics (>10 KHz Carrier Offset) | less than -50 dBc |
Non Harmonics (>50 KHz Carrier Offset) | NA dBc |
Reverse Power Protection | DC voltage: 30 V RF power: +36 dBm Watt |
Minimum Output Level | -120 dBm |
Maximum Output Level | +13 dBm |
Output Level Resolution | 0,1 dB |
Total Accuracy Forall Specified Output Level At 25 Degree C In Continuous Wave Mode | < 1 dB dB |
VSWR On All Operating Frequencies | 1.8 |
Memory (Minimum Storage Settings) | 16 |
Amplitude Modulation (AM) Operating Modes | Internal & External |
Minimum Amplitude Modulation Frequency (3 DB), F > 100 KHz | 20Hz Hz |
Maximum Amplitude Modulation Frequency (3 DB), F > 100 KHz | 20KHz KHz |
Modulation Depth | 0 to 100% % |
Resolution Of AM | 0.1% |
AM Distortion At 1 KHz | < 2 |
Frequency Modulation (FM) Operating Modes | Internal & External |
Minimum Frequency Modulation Frequency (-3 DB) Standard | 20Hz |
Maximum Frequency Modulation Frequency (-3 DB) Standard | 80KHz |
Minimum Frequency Deviation | 0.02 KHz |
Maximum Frequency Deviation | 100KHz KHz |
Resolution Of FM | < 1, Minimum 1 Hz |
Setting Error (at AF=1 KHz And 50% Max. Deviation) For FM | < (5 of FM deviation +300 Hz) |
Phase Modulation | Available |
If Available, Phase Modulation Operatinf Mode | Internal & External |
Minimum Phase Deviation | 0 Rad Radians |
Maximum Phase Deviation | 10 Rad Radians |
Resolution Of Phase Modulation | 1 % |
Setting Error (at AF=1 KHz) For Phase Modulation | < (5 of deviation +0.2 rad) |
Internal Modulation Generator For AM/FM/PM | 20Hz to 80KHz with resolution of 0.1 Hz |
Pulse Modulation | Available |
If Available, Pulse Modulation Operating Modes | Internal & External |
Rise And Fall Time | < 3 s ns |
On/Off Ratio | ≥ 40 dB dB |
Minimum Pulse Width | 100 μs to 1 s ns |
Input Level | TTL |
RF Digital Sweep Range And Width | 9 kHz to 3.0 GHz |
RF Digital Sweep Time Range | 10 ms to 1 s |
RF Analog Sweep | Not-Available |
If Available, RF Analog Sweep Range And Width | NA |
RF Analog Sweep Time Range | NA |
Pulse Generator | Not-Available |
If Available, Pulse Generator Operating Mode | NA |
Pulse Width | NA |
Pulse Delay | NA |
Pulse Period | NA |
Vector Modulation | Not-Available |
Internal Base Band Generator Bandwidth | NA MHz |
Arbitory Waveform Memory | NA Mega samples |
Modulation | NA |
Error Vector Magnitude (EVM) | 0 % |
Phase Modulator | Not-Available |
If Available, Range Of Modulating Signal (Wide Mode) | NA |
If Available, Range Of Modulating Signal (Narrow Mode) | NA |
Interface Available | USB Interface |
Standard Acessories (To Be Supplied) | Quick Start Guide, USB cable Country-specific power cord Documentation set (CD-ROM) 3-year return-to-Keysight warranty |
Power Requirements | 230 V +/-10% AC, 50 Hz +/- 3% |
Operating Temperature Range | 5 to 45 Degree C Degree C |
Operating Humidity (RH) | Yes Available % |
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. | Yes |
Test Report No. | NTH(SR)/EL(C)/2013/024M |
Test Report Date | 04/02/2013 |
Name Of The Lab | NTH Taramani, Chennai |
Warranty | 3 Years |